제목 TurboVap® EH 등록일 2018-11-13 10:43:08

TurboVap® EH solvent evaporator is a brand new addition to the TurboVap family designed to streamline a customer’s workflow following sample processing on Extrahera. The system builds on the solid foundations of the existing TurboVap product line and incorporates many new features.

 

TurboVap® EH solvent evaporation unit provides parallel evaporation of two collection racks from Extrahera™, and continues to utilise the highly efficient patented gas vortex shearing technology, synonymous with the TurboVap brand.

The TurboVap EH has many new and improved hardware features versus the old style TurboVap family, notably enhanced visibility, removable and replaceable nozzles, easily exchangeable manifolds to switch system configurations, evaporation flow gradients, drain port and touch screen interface. To complement the TurboVap EH is a rack holder which allows end-user to take their collection racks from Extrahera directly to the TurboVap EH without having to move sample vials/tubes to a dedicated TurboVap rack, seamless sample processing to evaporation.

Technical Specifications

Evaporation

Gas Supply and Connection

The system can operate using inert gas. Compressed air can be used but is not recommended with some solvents due to the possible risk of explosion. The gas tube supplied with the system has a 6 mm outer diameter. An adapter for connecting a gas tube with an outer diameter of 1/4" can be purchased separately.

Note: There is no regulator for the gas inlet supplied with the system. This can be purchased separately as an optional accessory (P/N 352281SP Air Control Unit and P/N 353480SP Supply Connection Set).

  • Minimum supply pressure: 4 bar (0.4 MPa, 58 PSI).
  • Required supply pressure for full flow capability: 6 bar (0.6 MPa, 87 PSI).
  • Maximum pressure: 9 bar (0.9 MPa, 130 PSI).
  • Required supply flow for full flow capability:
    • 48 positions: 200 litres/min
    • 24 positions: 160 litres/min

Water Bath Temperature Range

Ambient to 90°C, ± 2°C accuracy

Temperature Increase

Heating time from 20°C to 55°C is approx. 40 mins.

Gas Flow Range

The maximum gas flow depends on the gas supply pressure and flow, the number of available nozzles and how many that are open. The maximum gas flow for each nozzle:

  • 48 positions: 3.5 litres/min
  • 24 positions: 5.5 litres/min                  

Chemical Resistance

  • Formic acid 5 %
  • Acetic acid 10 %
  • Phosphoric acid 5 %
  • Propionic acid 5 %
  • Ammonium hydroxide 5 %
  • Triethylamine 5 %        

Racks and Tube Sizes

 

TurboVap EH sample/collection rack holder with 2 positions for the following Extrahera sample/collection racks:

  • 24 Positions, 12 x 75 mm Tubes
  • 24 Positions, 16 x 75 mm Tubes
  • 24 Positions, 18 x 75 mm Tubes

Interfaces

Touch Screen

7 Inch Touch Screen       

Auxiliary

Connection for end-point detection      

System

Fume Hood/Ventilation

The system must be either connected to ventilation system using the exhaust outlet at the rear of the system or placed in a well-ventilated fume hood or an equivalent enclosure to reduce the risk of exposure to harmful solvent vapours. The ventilation system or fume hood must be capable of exhausting 1 m3/min (35.3 ft3/min).

Connection: The exhaust hose supplied with the system is 3.8 meters (12.5 feet) and has a 50.8 mm (2") inner diameter.

Operating Temperature

18°C to 32°C

Storage Temperature

-25°C to 60°C

Humidity

20% to 90% RH (non-condensing)

Electrical Supply

100-127 V and 220-240 V at 50/60 Hz

Fuses

F10A at the power inlet (1 required)

Max Power Consumption

1000 VA

Weight

17 kg (37.5 lbs) when the water bath is empty and maximum 29 kg (63.9 lbs) with deionized water, rack, and tubes.

Dimensions (W x D X H)

400 x 400 x 390 mm (15.7" x 15.7" x 15.4") including the hinges at the side and exhaust at the rear. The height with the lid open is 590 mm (23.2").

Max Sound Level

75 dB(A)

Certifications

CE marked and CB and NRTL certified.

 


 

공지사항
Cat No. 제품명
415540 TurboVap® EH
413282 Test Tubes (16 x 75 mm, Uncap)
414574 Test Tubes (18 x 75 mm, Uncap)
C44651 Test Tubes (12 x 75 mm, Uncap)
415490SP TurboVap® EH Manifold (2 x 24 Nozzles)
415491 Sample/Collection Rack (24 Positions, 12 x 75 mm Tubes), Biotage® Extrahera
415492 Sample/Collection Rack (24 Positions, 18 x 75 mm Tubes), Biotage® Extrahera
415510 TurboVap® EH Sample/Collection Rack Holder (2 Positions)
415585 Sample/Collection Rack (24 Positions, 16 x 75 mm Tubes), Biotage® Extrahera